Polyacrylate material of low molecular weight. Non-volatile used for scale inhibition in sea water treatment. The product is miscible with water in all proportions. And is clear Liquid. to control sludge. USES of RXSOL Scale Hardness Stabilizer Hardness Control provide tolerance of feedwater quality fluctuations. The ready stock of Scale Hardness Stabilizer Hardness Control is in 25, 50, 220 Ltr packing.
Polyacrylate material of low molecular weight. Non-volatile used for scale inhibition in sea water treatment. The product is miscible with water in all proportions. And is clear Liquid. Scale Hardness Stabilizer Hardness Control is specialized Water treatment product to KEEP water Clear and Clean SLUDGE FREE.
RXSOL-33-5027-025 Scale Hardness Stabilizer is basically Polyacrylate phosphates combination with synthetic polymers. Very easy to use, provides flexibility in system operation and control over the operation of the auxiliary. The tool is designed to maintain the cleanliness of the system at unstable as feedwater.
To be most effective to prevent corrosion and scaling RXSOL-33-5027-025 Scale Hardness Stabilizer should be constantly adding to the system with a dosing devices. Less preferable to use gravitational dosing device, because preparation can evaporate when the water returns into the tank cascade.
Regularly enter solutions RXSOL-33-5027-025 Scale Hardness Stabilizer with a dosing device in feedwater recirculation outlet below which returns cascading water in the tank. If there is no recirculation of feedwater, the RXSOL-33-5027-025 Scale Hardness Stabilizer should be submitted in suction tube feeding pump. When using gravity dispenser the RXSOL-33-5027-025 Scale Hardness Stabilizer should be fed to the point of feed water tank or in cascade.
RXSOL-33-5027-025 Scale Hardness Stabilizer supply line should be higher than normal water level (about 1 meter) and as close as possible to the fence of water nutrient pump. RXSOL-33-5027-025 Scale Hardness Stabilizer to be diluted in distilled water or condensate in the dispensing tank and gradually continuously fed for 24 hours, keeping the system demand. The daily dosage is depend on the volume of the system, the condensate quality and purity, as well as the quality and quantity of the feed water system. For standard operating systems the dosage RXSOL-33-5027-025 Scale Hardness Stabilizer is about 1 liter a day.
Very large systems or in non-standard conditions will have a greater need for preparation. Many factors can affect the initial dose of the RXSOL-33-5027-025 Scale Hardness Stabilizer. The recommended initial dose of 2.5 to 5 liters per tonne of water system. After the initial filling of the product during operation of the system on a daily basis should perform a test to adjust the dosage. Low quality feedwater demands increase quantities of preparation.
The main objective of the program - to prevent fouling. The most effective way to fight c deposits is to use distilled water feed. RXSOL-33-5027-025 Scale Hardness Stabilizer created for removing water hardness instability.
Blowdown
Purge procedure is necessary for the effectiveness of any treatment program and system watershall be in accordance recommendations manufacturer's instructions. Purging is required to remove the precipitate dissolved and suspended solids. Normal regular purging with sufficient neutral of conductivity 700 micromho. A higher rate of conductivity (above 700 micromho) frequency blowdown should be increased. Additionally, it is recommended to wash weekly collector or separator pair (if any) to reduce the accumulation of sludge.
Appearance |
: Clear liquid |
Specific gravity at 25 º C (77 º F) |
: 1.2 |
Fire |
: off |
Freezing temperature |
: -6.6 º C (20 º F) |
pH |
: 5-7 |
Stability after freeze / that |
: yes |
Did you know, how to keep system scale and corrosion free, water CLEAR and Sludge free?
RXSOL-33-5027-025 Scale Hardness Stabilizer contains Polycarboxylate Phosphate and synthetic low molecular wt polymer to control sludge which results in the clean boiler water. USES of RXSOL-33-5027-025 control Hardness and provide tolerance of feedwater quality fluctuations.
Chemically one part of The RXSOL-33-5027-025 polymers keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during cleaning and maintenance operation.
While Other part of Phosphate which is used in RXSOL-33-5027-025 serve as deposit control agents by Iron dispersancy, main cause of sequestering deposits.
USES of RXSOL-33-5027-025 during sea water treatment, can help and keep WATER CLEAN and CLEAR.
RXSOL-33-5027-025 have antiscalant property which will help to formation of scale inside the boiler. This makes it profitable for users by savings of power and labor, and increase in production. As Uses of antiscalants is a prime necessity to meet up with production targets.
Specialized formulation designed to increase alkalinity of water and also used to reduce corrosion of feed water tank, lines & pump.
CORROSION REDUCTION
RXSOL-33-5027-025 Increases ph of the feed water reducing corrosiveness. it also increases alkalinity in water reducing scaling & corrosion of the system metal.
EASY SLUDGE REMOVAL
RXSOL-33-5027-025 helps in formation of non adherent sludge. it fluidises the sludge which is then removed easily during normal blow-down. non- toxic and non-corrosive liquid formulation and therefore can be handled easily.
Effectively works as Sludge Conditioner
Hardness Stabilizer (POC 3000) :
Polyacrylate material of low molecular weight.
Non-volatile used for scale inhibition in sea water treatment.
The product is miscible with water in all proportions. And is clear Liquid.
PH valve 5-7.
Density @ 20°C Approx. 40%.
Chemical Characterization Sodium Polyacrylate, Modified, Aqueous solution.
Solidification temperature -20°C.
Flash point >100°C.
Ignition temperature >200°C.
Key Features & Benefits:-
Minimizes corrosion of feed water tank, Lines and pump
Imparts water and sludge conditioning to minimize scaling and deposition
Compatible with other treatment Chmicals
Completely biodegradable chemicals
Its antiscale property helps and Prevent from Scaling
Minimum downtime required for descaling
Multipurpose,therefore easy to use
Formation of Scale is major issue and contol of scale makes Effectively heat transfer which Increase productivity.
Testing:
Dosage and frequency RXSOL-33-5027-025 Scale Hardness Stabilizer controlled blowdown simple tests on the quality of the boiler water.Tests include checking parameters such as hydrate alkalinity, conductivity, phosphates, stiffness feedwater and condensate pH. For more information about the testing procedure, refer to Table control the amount and dosage RXSOL-33-5027-025 Scale Hardness Stabilizer Control and Dosage Chart or contact representative of Rx Marine International.
CHARACTERISTICS :
- Has dispersant properties.
- Converts crystals.
- Comprehensive protection.
- Air conditioning sludge.
- Multi-tool.
- Prevents scale.
- Easy to use and testing.
BENEFITS
- Do not allow the particles to stick together.
- Do not allow the build-up of scale on pipes.
- Provides efficient heat transfer.
- Soft sludge" can be easily removed by blowing.
- Redundant components ensure protection.
- Increases in operation.
- Reduces the need for acid peels.
- Saves maintenance costs Kotel.
- Control of corrosion caused due to low.
- pH levels in the condensate system.
- Controls alkalinity.
- Controls the formation of a new scale.
- Convenient for operator.
RXSOL-33-5027-025 Scale Hardness Stabilizer Sludge Conditioner most commonly used in low and medium pressure boilers, to keep WATER CLEAR and Sludge free.
RXSOL-33-5027-025 Scale Hardness Stabilizer control sludge and sediment deposition by adsorption on sludge surfaces; particles are soft, do not stick together, smoothly removed by purging. RXSOL-33-5027-025 Scale Hardness Stabilizer contained component, iron oxide passivation and not giving cheance to spread throughout system. In addition to controlling the alkali content, scale and sediment, RXSOL-33-5027-025 Scale Hardness Stabilizer protects the condensate system (Steam superheater) from corrosion caused by low pH. In conjunction with RXSOL-33-5027-025 Scale Hardness Stabilizer provides the most modern, safe and effective program to protect the boilers on ships.
Phosphate and synthetic polymer Based water treatment chemicals to control sludge. RXSOL-33-5027-025 Scale Hardness Stabilizer Hardness Control manufacturer ans supplier in Mumbai, Gandhidham Surat Gujrat, Chennai, Ennore, Visakhapatnam VIZAG Andhra Pradesh, Kolkata, Haldia, Paradip, Fujairah, Sharjah, Ajman, Abudhabi, Muscat Oman, Canada BE, Nairobi Mombasa, Kenya, Jinja Kampala, Uganda