Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure boilers which results in the clean boiler water. USES of RXSOL BOILPLEX AT Hardness Control provide tolerance of feedwater quality fluctuations. The ready stock of BOILPLEX AT Hardness Control is in 25, 50 Ltr packing.
BOILPLEX AT Hardness Control is specialized Boiler Water treatment product to KEEP Boiler water Clear and Clean SLUDGE FREE.
Boilplex AT is basically phosphates combination with synthetic polymers. Very easy to use, provides flexibility in system operation and control over the operation of the auxiliary and exhaust gas heaters on the boats. The tool is designed to maintain the cleanliness of the boiler at unstable as feedwater.
To be most effective to prevent corrosion and scaling using drug Boilplex AT the drug should be constantly adding to the boiler system with a dosing devices BWT Dosing System. Less preferable to use gravitational dosing device, because preparation can evaporate when the water returns into the tank cascade.
Regularly enter solutions drugs Boilplex AT with a dosing device BWT Dosing System in feedwater recirculation outlet below which returns cascading water in the tank. If there is no recirculation of feedwater, the drug should be submitted in suction tube feeding pump. When using gravity dispenser the drug should be fed to the point of feed water tank or in cascade. Drug supply line should be higher than normal water level (about 1 meter) and as close as possible to the fence of water nutrient pump. Boilplex AT to be dissolved in distilled water or condensate in the dispensing tank and gradually continuously fed for 24 hours, keeping the system demand. The daily dosage is depend on the volume of the system, the condensate quality and purity, as well as the quality and quantity of the feed water system. For standard operating systems the dosage Boilplex AT is about 1 liter a day.
Very large systems or in non-standard conditions will have a greater need for preparation. Many factors can affect the initial dose of the drug. The two most important factors - quality feedwater and the boiler. The recommended initial dose of 2.5 to 5 liters per tonne of water system. After the initial filling of the product during operation of the system on a daily basis should perform a test to adjust the dosage. Low quality feedwater demands increase quantities of preparation, as well as leaching of the polluted water from the boiler of the boiler due to the settling of particles on bottom of the boiler during system shutdown. This in turn entails the need for additional purging and increase the amount of drug.
The main objective of the program - to prevent fouling. The most effective way to fight c deposits is to use distilled water feed. Boilplex AT created for removing water hardness instability.
Blowdown
Purge procedure is necessary for the effectiveness of any treatment program and boiler watershall be in accordance recommendations manufacturer's instructions. Purging is required to remove the precipitate dissolved and suspended solids. Normal regular purging with sufficient neutral of conductivity 700 μmho. A higher rate of conductivity (above 700 μmho) frequency blowdown should be increased. Additionally, it is recommended to wash weekly collector or separator pair (if any) to reduce the accumulation of sludge.
Testing:
Dosage and frequency Boilplex AT controlled blowdown simple tests on the quality of the boiler water.Tests include checking parameters such as hydrate alkalinity, conductivity, phosphates, stiffness feedwater and condensate pH. For more information about the testing procedure, refer to Table control the amount and dosage Boilplex AT Control and Dosage Chart or contact representative of Rx Marine International.
CHARACTERISTICS :
- Has dispersant properties.
- Converts crystals.
- Comprehensive protection.
- Air conditioning sludge.
- Multi-tool.
- Prevents scale.
- Easy to use and testing.
BENEFITS
- Do not allow the particles to stick together.
- Do not allow the build-up of scale on pipes.
- Provides efficient heat transfer.
- Soft sludge" can be easily removed by blowing.
- Redundant components ensure protection.
- Boiler Cleaner.
- Increases in operation.
- Reduces the need for acid peels.
- Saves maintenance costs Kotel.
- Control of corrosion caused due to low.
- pH levels in the condensate system.
- Controls alkalinity.
- Controls the formation of a new scale.
- Convenient for operator.
Appearance |
: Clear liquid |
Specific gravity at 25 º C (77 º F) |
: 1.056 |
Fire |
: off |
Freezing temperature |
: -6.6 º C (20 º F) |
pH |
: 13.4 |
Stability after freeze / that |
: yes |
Did you know, how to keep BOILER water CLEAR and Sludge free?
RXSOL BOILPLEX AT Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure Boilers which results in the clean boiler water. USES of RXSOL BOILPLEX AT Hardness Control provide tolerance of feedwater quality fluctuations.
Chemically one part of The polymers used in BOILPLEX AT keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during boiler cleaning and maintenance operation.
While Other part of Phosphate which is used in BOILPLEX AT serve as deposit control agents by Iron dispersancy, main cause of sequestering deposits.
USES of RXSOL BOILPLEX AT boiler water treatment, can help BOILER WATER CLEAN and CLEAR.
Sludg Conditioner to Clear Boiler Water.
Boilplex AT control sludge and sediment deposition by adsorption on sludge boiler surfaces; particles are soft, do not stick together, smoothly removed by purging. Boilplex AT contained component, iron oxide passivation and not giving cheance to spread throughout system. In addition to controlling the alkali content, scale and sediment, Boilplex AT protects the condensate system (Steam superheater) from corrosion caused by low pH. In conjunction with Boilplex AT provides the most modern, safe and effective program to protect the boilers on ships.
RXSOL BOILPLEX AT Hardness Control Sludge Conditioner most commonly used in low and medium pressure boilers, to keep BOILER WATER CLEAR and Sludge free.
Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure boilers RXSOL BOILPLEX AT Hardness Control manufacturer ans supplier in Mumbai, Gandhidham Surat Gujrat, Chennai, Ennore, Visakhapatnam VIZAG Andhra Pradesh, Kolkata, Haldia, Paradip, Fujairah, Sharjah, Ajman, Abudhabi, Muscat Oman, Canada BE, Nairobi Mombasa, Kenya, Jinja Kampala, Uganda