Accumulation of dust from this cargo on deck or in proximity to cargo spaces shall be removed as quickly as possible. Consideration shall be given to carefully cleaning exposed radio communications equipment to which dust might adhere, such as radar, radio, aerials, vhf installations, AIS and GPS. Hosing with sea water should be avoided.
HBI CARGO Hold Wash Concentrate RX  is a versatile all-purpose QUALITY marine cleaning solution. It can be used as a powerful stand-alone cleaner for HBI CARGO .  it can be used as a powerful\ stand alone cleaner  for HBI CARGO dust and deposition  .
 

Product Application: 

FEATURES & BENEFITS :-------------------
$ Heavy duty HBI CARGO  remover action
$ Can be diluted to suit cleaning needs
$ Environmentally friendly
$ Safe to use in occupied / covered areas
$ Reduces turnaround times
$ Can be easily applied by ship's crew
$ using an RXSOL Application Set

Product Dose: 

Product Note: 

Features & Benefit:-

  • Heavy duty HBI CARGO cleaning power
  • Can be diluted to suit cleaning needs
  • Environmentally friendly
  • Safe to use onto the occupied areas /covered areas
  • Reduces the turnaround times
  • Cam be easily applied by ship’s crew

 

Product Technical Specification: 

Remarks: 

HBI at Elevated Temperatures
The Master of the ship must notify the port authorities if hydrogen gas is detected in the ship holds or if abnormal temperatures are measured in the HBI cargo holds. The Harbor Master and qualified personnel are responsible for executing the action plan when a ship or barge arrives with HBI at the following temperature levels:

A. Greater Than 65° Celsius but Less Than or Equal to 80° Celsius
Proceed with the following actions:

1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book.
2 >  Unload the holds in the assigned zone and immediately transfer the HBI to the storage yard zone as described in PART II, Section 5.4 of this guide.

B. Temperature Greater Than 80° Celsius and Less Than or Equal to 150°
Celsius

Proceed with the following actions:
1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.
2 >  Unload the holds with HBI at temperature less than 65º Celsius first, then those containing HBI between 65º and 100º Celsius. Continue unloading HBI with temperatures between 100º and 150º Celsius in the
first transfer station, using the movement sense of the belt as a
reference.
3 >  Transfer the HBI from the unloading zone clean and free of debris and flammable material, such as coal, coke and wood to the storage yard indicated by the client as follows:
Transfer the HBI during a maximum of three-minute intervals, and dose (i.e., mix the hotter with the cooler material to have an average temperature lower than the hottest one – no water to be used) the HBI that is at temperatures between 100° and 150° Celsius with cooler material for a maximum of two minutes. Stop the vibrating feeders for about five minutes, but keep the conveyor belts in motion. Repeat these steps until finished with HBI removal. While transferring the HBI, inspect the belt transfer system for any sign of overheating. In case of belt overheating, stop the HBI dosing and transfer but keep the transfer belts in motion until they cool. Take special care to avoid pouring water into hoppers and other equipment. Use a front-end loader to spread the HBI to a level of approximate 30 centimeter height to stop the reoxidation,  Verify that the belts are cooled down and resume HBI transfer per
the previous instructions.

C . Greater than 150° Celsius
Proceed with the following actions:
1 > Before unloading the holds, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.
2 > Position the HBI with temperatures greater than 150° Celsius at the end of the reception area and spray with pressurized water. In this case, there is no option but to momentarily cool down the HBI.
3 >  When the temperature is reduced to between 80º and 150° Celsius proceed with the steps described in 6.3.2.2. Caution: Do not spray water on hot HBI that is steaming (i.e., emitting water vapor). 

Procedure If Hydrogen Concentration Is Over 1% (25% LEL)
1 > Inform the shipper immediately and seek expert advice.
2 > Keep the natural surface ventilation open at all times
3 > Monitor LEL in the holds continuously until level drops to less than 25 %.
4 > Avoid any possible ignition source on the vicinity.
5 > Care shall be taken as to prevent any spark generation.
6 > Monitor the hydrogen concentration in the holds and keep the surface ventilation (either natural or mechanical) until values fall below 1%.
7 > When hydrogen levels are within safe values, proceed as normal.
8 > On the contrary, additional ventilation should be applied to the space if available and re-testing should be conducted after a suitable interval.
9 > Contact the P & I Club and Shipper and follow the instructions of the appointed expert or surveyor.
10 > At sea, do not open the troubled hold without explicit instructions from the shipper or appointed expert or surveyor.
11 > Ensure there are no possible sources of ignition near the cargo spaces, adjacent spaces or open decks.

Articles: 

HBI Cargo Residue Cleaner Chemical is helpful to  clean HBI cargo stain by chemicals cleaning and reactive principle. We are  HBI CARGO Residue cleaner supplier in Paradip, Haldia, Hazira, Mundra, Kandla, Ennore, Kochin, Visakhapatnam, Sohar, Muscat, Fujairah, Dubai, Sharjah, Mumbai, Manglore and Goa, Ruwi Barka, Abudhabi, Ajman, Sudan, Yemen, Canada

Hashtags: 
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride
Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates

About Us

We are one of largest marine chemical manufacturing company in Asia. Our specialization in marine, oil field, shipping industry. Since 1995 our group team continiously developing our product to achieve best in quality and services. Specially in shipping industries we make our position on TOP among all supplier. All shipchandler and shipping company of UAE - Middle East are well known to us and DUBI CHEM Marine International have more then 1800 global regular client to achieve our monthly target more then 360 MT .   DUBI Chem Marine International have very strong distribution network as well in INDIA also to complete supply directly on ship vessel -  http://www.westindiachemical.com/ (Kandla,Mundra,Sikka) ,  http://marinechemical.in/ (Mumbai,JNPT,Goa,Manglore) , http://www.vizagchemical.com/ (Vizag-Visakhapatnam,Gangavaram) , http://ennoreindiachemical.com/ (Chennai,Ennore,Kochin) , http://eastindiachemicals.com/ ( Kolkata, Haldia, Paradip ) etc... For INDIA supply directly mail us on rxmarine@gmail.com or feel free to call us 0091-9821214367 ...
 

Latest Tweets

Follow Us

Twitter icon
Facebook icon
Google+ icon

ISO 9001 Certificate

STOCK Point : UAE, OMAN, KENYA, INDIA, CANADA

Call Us : +971 9 2242524 / 09 2242534
Support:+971 9 2235488

Email : dubichemical @ gmail.com
            
WhatsApp::: +  91 8752916666 for TECHNICAL SUPPORT
WhatsApp::: +971 567213066   for Product Inquiry ( Only Whatsapp )
WhatsApp::: 00971 569159739 for complain / report  ( Only Whatsapp )

CHEMICAL DISTRIBUTOR IN UAE GULF MIDDLE EAST

Address : الحيل Plot no. 37A, block -L, Next to GULF Ready Mix Al Hayl Industrial Area - Fujairah - United Arab Emirates

X

Request for Quote and Get Heavy Discount on Price